2025 Energy Code · Climate Zone 8

Title 24 Climate Zone 8: ADU Requirements

What the 2025 California Energy Code's prescriptive package requires for a new detached ADU in Climate Zone 8, and how those requirements change the MEP design.

Order MEP Plans + Title 24 About Title 24 reports

Where Climate Zone 8 is

Of the California places we cover, 44 are mostly in Climate Zone 8, across 2 counties: Los Angeles County, Orange County. Together they issued 14,798 ADU building permits from 2021 through 2025. Zones follow ZIP-code boundaries, so we confirm the zone from the project address before running the Title 24 report.

2025 prescriptive requirements for a new detached ADU

For a new detached ADU in Climate Zone 8, the 2025 prescriptive package sets these zone-specific targets.

WindowsU-factor 0.30 or lower; SHGC 0.23 or lower; total area up to 20% of floor area (west-facing up to 5%)
Attic, high-performance optionR-38 ceiling; below roof deck: R-19
Attic, ducts-inside optionR-38 ceiling plus radiant barrier; ducts and air handler in conditioned space
Framed wallsAssembly U-factor 0.048 or lower
Cool roofNot required
Whole-house fanRequired, 1.5 cfm per sq ft of floor area (units of 500 sq ft or less exempt)
Space heating and coolingHeat pump (other systems through the performance approach)
Water heatingHeat pump water heater; units of 500 sq ft or less, or one bedroom or fewer, have simpler options
Solar PVkW = (floor area x 0.586) / 1000 + 1.37; none required under 1.8 kWdc (about 734 sq ft or smaller for a single ADU)

An attached ADU or a garage conversion is an addition under the Energy Code, not new construction, so it follows the addition requirements instead. Solar PV is not required for additions.

Design temperatures across Climate Zone 8

The zone sets the energy targets, but the HVAC is sized from the local design temperature, and that varies inside a zone. Among the places we cover here, the 1% summer design temperature ranges from 84°F in Inglewood to 92°F in Fullerton, and the coldest winter design temperature is 30°F in Fullerton. That spread is why we run a Manual J for each address instead of using a zone-wide rule of thumb.

Places in Climate Zone 8

PlaceCountyElectric utilityADU permits 2021–25
FullertonOrangeSouthern California Edison (SCE)2,171
Garden GroveOrangeSouthern California Edison (SCE)2,046
AnaheimOrangeAnaheim Public Utilities1,713
DowneyLos AngelesSouthern California Edison (SCE)1,020
LakewoodLos AngelesSouthern California Edison (SCE)1,016
Santa AnaOrangeSouthern California Edison (SCE)956
NorwalkLos AngelesSouthern California Edison (SCE)494
LynwoodLos AngelesSouthern California Edison (SCE)492
Culver CityLos AngelesSouthern California Edison (SCE)416
OrangeOrangeSouthern California Edison (SCE)400
InglewoodLos AngelesSouthern California Edison (SCE)348
Buena ParkOrangeSouthern California Edison (SCE)343
South GateLos AngelesSouthern California Edison (SCE)331
La HabraOrangeSouthern California Edison (SCE)331
BellflowerLos AngelesSouthern California Edison (SCE)292
GardenaLos AngelesSouthern California Edison (SCE)259
ParamountLos AngelesSouthern California Edison (SCE)253
HawthorneLos AngelesSouthern California Edison (SCE)187
Bell GardensLos AngelesSouthern California Edison (SCE)184
Mission ViejoOrangeSouthern California Edison (SCE)147
ComptonLos AngelesSouthern California Edison (SCE)145
StantonOrangeSouthern California Edison (SCE)144
Yorba LindaOrangeSouthern California Edison (SCE)138
PlacentiaOrangeSouthern California Edison (SCE)119
TustinOrangeSouthern California Edison (SCE)86
Huntington ParkLos AngelesSouthern California Edison (SCE)85
BreaOrangeSouthern California Edison (SCE)85
ArtesiaLos AngelesSouthern California Edison (SCE)85
Lake ForestOrangeSouthern California Edison (SCE)82
CypressOrangeSouthern California Edison (SCE)73
Hawaiian GardensLos AngelesSouthern California Edison (SCE)59
BellLos AngelesSouthern California Edison (SCE)52
CudahyLos AngelesSouthern California Edison (SCE)48
CerritosLos AngelesSouthern California Edison (SCE)40
MaywoodLos AngelesSouthern California Edison (SCE)31
Villa ParkOrangeSouthern California Edison (SCE)23
Los AlamitosOrangeSouthern California Edison (SCE)21
La PalmaOrangeSouthern California Edison (SCE)19
IrvineOrangeSouthern California Edison (SCE)14
CommerceLos AngelesSouthern California Edison (SCE)13
La Habra HeightsLos AngelesSouthern California Edison (SCE)12
Rancho Santa MargaritaOrangeSouthern California Edison (SCE)11
LawndaleLos AngelesSouthern California Edison (SCE)8
Trabuco Canyon (unincorp.)OrangeSouthern California Edison (SCE)6

Sources

Requirements shown are the 2025 prescriptive package (effective January 1, 2026) for newly constructed single-family buildings, which includes new detached ADUs. A performance (computer-modeled) approach can trade some items against others. Your Title 24 report confirms what applies to your project.

Need MEP plans and a Title 24 report in Climate Zone 8?

We prepare both from the same design, so the energy model and the equipment on the plans agree.

Start My Order